🔴 DANGER ACTIVE — RUB-043 Kalyan Road Underpass: Water level 524mm, Siren & Beacon ON    |    🟡 ALERT — RUB-057 Thane Junction: Water level 318mm and rising    |    ✅ RUB-102 Pune Bypass: Normal — 42mm    |    âš« RUB-078 Nashik: OFFLINE — Last seen 18 min ago    |    ✅ RUB-119 Aurangabad: Normal — 18mm    |    📡 System heartbeat OK    |    VPS: FGServer.jenix.in    
⚠️
DANGER - RUB-043 Kalyan Road Underpass  |  Water Level: 524mm  |  Siren & Beacon Active  |  Alert since 09:15:42 IST
🏛️ Approved for Government Deployment  Â·  NDRF Compatible

Jenix FloodGuard

RUB Water Level Monitoring & Alarm System
जल सुरक्षा निगरानी प्रणाली

Real-time flood detection for Railway Under Bridges and low-lying roads — automated danger alerts, complete audit trail, and offline-resilient operation for uninterrupted public safety.

500+
Locations Ready
2s
Alert Response
99.9%
Uptime SLA
24/7
Monitoring
âš¡
2-Second Alert Response
Real-time MQTT telemetry with automated FCM push alerts
🔆
Solar Powered — Always On
Operates 24/7 even during grid power failure or monsoon
📶
Offline Resilient
Local alarm logic runs without internet — safety first
📋
Government-Grade Audit Trail
Every action logged with user, session, timestamp & location
Live Monitoring Dashboard — लाइव निगरानी डैशबोर्ड
LIVE DATA
Refreshed just now
RUB-043 — Kalyan Road Underpass
Thane District, Maharashtra  Â·  Device: RUB043-CTRL01  Â·  FW v1.0.2  Â·  Mount: 1200mm
DANGER / खतरा
Last Update
Just now
जल स्तर / Water Level
500mm âš 
300mm
524
mm
Distance: 676 mm
⚠ DANGER / खतरा
🔋
Battery / बैटरी
12.4V
Solar: 17.8V
● Charging
📡
WiFi RSSI / सिग्नल
-65 dBm
SIM: 4G  Â·  Signal: ███░
● Good Signal
💧
300mm Switch / स्विच
TRIGGERED
Contact: CLOSED
âš  Active
🚨
500mm Switch / स्विच
TRIGGERED
Contact: CLOSED
âš  Active
🕐
Incident Duration
00:14:23
Started: 09:15:42 IST
ACTIVE
💓
Heartbeat / हार्टबीट
● Online
Firmware: v1.0.2
ESP32-S3 OK
Network Status / नेटवर्क स्थिति All Online
📶
WiFi
Connected
🌐
Internet
Available
📱
SIM Status
4G Connected
📊
Signal / RSRP
-82 dBm · 3 Bars
🏢
Operator
Jio 4G
🔗
Gateway / WAN IP
49.34.xxx.xxx
🔄
MQTT Broker
Connected
🔐
MAC Bind
Verified ✓
Relay Status / रिले स्थिति Active outputs shown
🔊 Siren / साइरन
Pattern: 10s ON / 20s OFF
🔴 Beacon / बीकन
Continuous ON
📢 Voice / आवाज
Repeat every 30s
🚧 Barrier / बैरियर
Future integration
⚠️ Danger active since 09:15:42 — Beacon remains ON even if alarm is muted
Control Panel / नियंत्रण पैनल  Â·  Logged in as: Vendor Admin — All permissions active
🔒 All actions require confirmation and are permanently logged in audit trail with user, session ID, device name, and timestamp.
Recent Audit Log — हालिया ऑडिट लॉग View All Logs →
Time / समय Event / घटना Location Details / विवरण By / द्वारा
09:15:42 DANGER RUB-043 Water 524mm continuous >60sec — Siren & Beacon activated System / Auto
09:15:44 FCM PUSH RUB-043 Push notification sent to 8 authorized users System / Auto
09:12:30 ALERT RUB-057 Water 318mm continuous >60sec — Alert level confirmed System / Auto
08:45:00 OFFLINE RUB-078 Heartbeat timeout — No response for 5 minutes System / Auto
08:30:15 DRY RUN RUB-102 Siren test completed — Duration 10 sec, Result: PASS operator_rub102
07:55:00 MUTED RUB-043 Alarm muted — Reason: Site inspection ongoing. Beacon remains ON. operator_rub043
07:30:00 CLEARED RUB-043 Danger auto-cleared — Water <450mm for 5 min, All relays OFF System / Auto

Why FloodGuard by Jenix?

Built to government audit standards — every alert, every action, fully accountable

âš¡
Real-Time Monitoring

Water level updates every 2 seconds during danger events. RS485 ultrasonic sensor with 5-reading filtered average eliminates false alarms from vehicle splashes, animals, or debris.

🔴
Instant Multi-Channel Alerts

FCM push notifications to all authorized Android and PWA users simultaneously. Siren, beacon, and prerecorded voice announcement trigger locally within 2 seconds of confirmed danger.

🔆
Solar Powered — Zero Downtime

Independent solar panel with battery backup ensures continuous operation through monsoon, grid failure, and extreme weather conditions — exactly when flood risk is highest.

📶
Offline Resilient Architecture

ESP32-S3 runs complete local safety logic independently. Internet loss does not affect siren, beacon, or voice announcement. Offline events sync automatically when connectivity returns.

📋
Complete Audit Trail

Every action — mute, force-clear, dry-run, config change — logged with user ID, login ID, session ID, device name, IP address, and timestamp. Meets government accountability requirements.

🏢
Multi-Location Management

Vendor-level, department-level, and location-level hierarchy with role-based permissions. Monitor hundreds of RUB sites from a single dashboard with region and division filters.

FloodGuard Login

Sign in to load live VPS data.